Capacities
Capacities from 800 to 50,000 kW
Ratings
Ratings from 200 to 68,000 kg/h steam
Design
Design pressure up to 43 bar-g
Optimization
Optimization of boiler and ancillary equipment
Plant-specific
Plant-specific economizers and superheaters
Special boilers
if applicable combined with water tube sections
| Model | Fuel | Steam rating (kg/h) | Heat capacity (kW) | Pressure |
|---|---|---|---|---|
| TDL | Oil/gas | 630 – 4.000 | 420 – 2.600 | 0,7 – 1 bar-g |
| OPTI | Oil/gas | 1.000 – 34.000 | 650 – 22.000 | 8 – 20 bar-g, max 36 bar-g |
| OPTI-TWIN | Oil/gas | 20.000 – 68.000 | 13.000 – 44.000 | 8 – 20 bar-g, max 36 bar-g |
| GLOBAL | Oil/gas | – | 1.000 – 10.000 | 4 – 10 bar-g, max 110°C |
| GLOBAL-H | Oil/gas | – | 1.000 – 10.000 | 4 – 16 bar-g, max 32 bar-g, max 240°C |
| TVB | Oil/gas | – | 12.000 – 25.000 | 4 – 10 bar-g, max 110°C |
| TVB-H | Oil/gas | – | 12.000 – 22.000 | 4 – 32 bar-g, max 240°C |
| TVB-TWIN | Oil/gas | – | 22.000 – 44.000 | 4 – 32 bar-g, max 240°C |
| COMBO | Oil/gas | 5.000 – 55.000 | 3.000 – 50.000 | Op til 40 bar-g, max 400°C |
| SPECIAL BOILERS | Oil/gas | Op til 68.000 | Op til 50.000 | Op til 43 bar-g, design dependent |
THERMAL OIL BOILERS
Type
TOB-H (horizontal), TOB-V (vertical). CE marked
Fuel
Fuel: Oil/gas, Electric heating
Heat capacity
TOB-H: 100 – 5.000 kW, TOB-V: 100 – 5.000 kW. Please contact us if you need a higher capacity
Pressure
Up to 10 bar(g), max 350°C
Expansion tank (ET)
ET is made as a horizontal tank and must always be placed 2 m above the highest point of the thermal oil system.
Design data:
- Desing norm: EN 13445-3:2009
- Design pressure: 0,5 bar(g)
- Max. temp.: 300°C
- Min temp.: 20°C
- Pressure test: 2 bar(g)
- Media: Thermal Oil (mineral oil)
- Plate thickness: 4-6 mm
- Plate material: S 235 JR
- Supplied as standard with manhole and without N2 dosing. Can also be ordered without manhole or with N2 dosage.
N2 dosing at hot oil temperature ≥ 250 °C.
Collection tank (CT)
CT is performed as a horizontal tank and is placed under the expansion tank (ET), where it is connected to the thermal oil system on the return line before the circulation pump(s). Overflow and drains from ET are connected at the top of the CT. Similarly, the CT vent pipe is passed up into the ET.
Design data:
- Desing norm: EN 13445-3:2009
- Design pressure: 0,5 bar(g)
- Max. temp.: 350°C
- Min temp.: 20°C
- Pressure test: 2 bar(g)
- Media: Thermal oil (mineral oil)
- Plate thickness: 4-6 mm
- Plate material: S 235 JR
Delivered as standard without manhole. Can be ordered with manhole.
A separate drain and fill pump is connected between the CT and the thermal oil system.
Deareator tank (DT)
DT is made as a vertical tank and is placed under the expansion tank (ET), where it is connected to the thermal oil system on the return line.
The Tangential thermal oil entry in the deaerator ensures optimal oxidation.
Design data:
- Desing norm: EN 13445-3:2009
- Design pressure: 0,5 bar(g)
- Max. temp.: 300°C
- Min temp.: 20°C
- Pressure test: 2 bar(g)
- Media: Thermal oil (mineral oil)
- Plate thickness: 4-6 mm
- Plate material: S 235 JR
Thermo clutch (TC)
TC is a hydraulic Thermo clutch. In practice, TC provides independency of flow requirement for the heater, which enables a standardization of units for different capacitys. This technology ensures better boiler performance, lower energy consumption and optimized pump sizes.
Design data:
- Desing norm: EN 13445-3:2009
- Design pressure: 10 bar(g)
- Max. temp.: 300°C
- Min temp.: 20°C
- Pressure test: 17 bar(g)
- Media: Thermal oil (mineral oil)
- Plate thickness: 4-6 mm
- Plate material: S 235 JR
Air-preheater (APH)
APH comes with a non-corrosive air pre-heater with a hybrid cross and counter flow design that has been validated with extensive CFD analysis.
Modular APH helps to maintain effeciency even under part load conditions.
System efficiency and NOx emmisions are opposing factors that are taken into account when designing the APH.
Design data:
- Design pressure: 0,4 bar(g)
- Max. temp. flue gas: 400°C
- Max. temp. air out: 150°C
- Media: Flue gas to air
Burner and control panel
Danstoker supplies N-gas, oil or combi- burners for the entire series of our Thermal Oil Boilers (TOB).
Emission and efficiency requirements are crucial for the choice of burner type.
The control panel can either be manufactured as a simple mechanical control unit or optionally with a Siemens PLC.
The safety equipment on the TOB is also integrated in the control panel, which ensures simple and safe operation.